Dynamix DW-2/4 FXO SIP Gateway User Manual
Hunt - Define the hunt group function.
None – Disable this function
Group – The call will search other ports to be the destination with the same group if
the origin destination is busy.
All – The call will search other ports to be the destination with the same type if the
origin destination is busy.
2 Press Add Data button to save the configuration and press the Routing
Table button again to reload the configuration. (see figure 3.16)
Figure 3.16: New Special Routing
The explanation of figure 3.16 is as below:
When the user dial 0 with the first digit of the numbers (from IP side). The
numbers you dial is between 1 and 10 digits. If this call matches the rule, it will
be transferred to the FXO port whose E164 number is 001.
3 Please Commit it and Reboot the system if the configuration is
finished.