Step 5: Create a new H.323 DM Group “1” and DM detail is show as follows:
H.323 Incoming Call DM Setting:
Matched Pattern: 5(pattern to be matched)
Group ID: 1-add002 (belong to this DM group)
Insert: The Insert digits
H.323 incoming call
Dialed number: 582265699
Match the pattern 5
Add 002 (Insert)
New dialed number becomes 002582265699
Step 5: Also create a new SIP DM Group ‘2” and DM detail is show as follows:
SIP Incoming Call DM Setting:
Matched Pattern: 113 (pattern to be matched)
Group ID: 2-sophie (belong to this DM group)
Drop: 113 (drop digits)