18 Rockwell Automation Publication 1441-UM003A-EN-P - May 2011
Chapter 2 FRF Frequency Response Function Extension Module
FRF Module Setup
There are three parameters that have already been configured to make the setup
easier. These are the measurement parameters that are already configured for you:
Pre-trigger delay – set to 10% of block length
Trigger level – set to 10% of input range
Good Coherence- 80% threshold
All other settings can be configured on the Setup screen in the FRF extension
module.
1. From the Main Menu, select the FRF icon and press Enter.