Figure 13.
b. Line #2 of FXO Gateway setting, see Figure 14.
An FXS port 2 incoming call routes to FXO port 2 configuration example.
Incoming Call Type : VOIP
Matched Prefix : 1002
Matched Length : 0
No Answer Timeout : 30 (MUST be longer than 10 seconds).
Outgoing Type : FXO
Hunting Type : selected anyone.
Routing List : 01. Line 2 ; 02. None. ; 03. None ; 04. None.
Figure 14.
c. Line #3 of FXO Gateway setting, see Figure 15.
An FXS port 3 incoming call routes to FXO port 3 configuration example.
Incoming Call Type : VOIP
Matched Prefix : 1003
Matched Length : 0
No Answer Timeout : 30 (MUST be longer than 10 seconds).
Outgoing Type : FXO
Hunting Type : selected anyone.
Routing List : 01. Line 3 ; 02. None. ; 03. None ; 04. None.